Hacker Newsnew | past | comments | ask | show | jobs | submitlogin

there are diy systems with threaded connectors, pre-vacuumed units and linesets filled with refrigerants.



True, but those linesets introduce other downsides. They can't be cut to length, so you often have to have unsightly loops of extra line set somewhere, and the loops can potentially trap the oils that mix with the refrigerant to lubricate the compressor. They're also much more expensive, and anecdotally, I've heard of leaks from over/under tightening the threaded connections.

Not to mention, installing them without an EPA 608 certification is technically illegal. MrCool and others that use them are relying on the EPA being understaffed and unlikely to pursue homeowners, but their stance on it is perfectly clear:

"Is technician certification required to install an R-410A mini-split?

Yes. Adding or removing refrigerant from a mini-split as part of installation, and/or connecting or disconnecting hoses or pre-charged lines requires a section 608 technician certification. Activities reasonably expected to violate the integrity of the refrigerant circuit include but are not limited to: Attaching or detaching hoses and gauges to and from the appliance; adding or removing refrigerant; adding or removing components; and cutting the refrigerant line."

https://www.epa.gov/section608/epas-refrigerant-management-p...


>True, but those linesets introduce other downsides. They can't be cut to length, so you often have to have unsightly loops of extra line set somewhere, and the loops can potentially trap the oils that mix with the refrigerant to lubricate the compressor.

well, i run my through crawlspace. had only a small extra loop. in crawlspace.

>They're also much more expensive,

per unit - yes. but... if you doing to diy mini-split not with precharged lineste, you need vacuum, refrigerant and probably license to buy it. it raises cost and make it viable if you plant to install multiple units (have coworkers that did it). if you want to get it professionally install, than in addition to ~$1.4k for 2ton unit you look into $6k-$8k for labor. Those were prices year ago for install in garage with 240v line connected to 40amp breaker available at install location.

>Not to mention, installing them without an EPA 608 certification is technically illegal.

technically, i guess much of the work done by home owners must be done by certified professionals and get approvals and inspections.