>Although, we don't know how similar the two projects are

They are similar in that the requirements for tank size are the same and the dirt is the same (same property). What is different is caused by the regulations. The style put in in 1983 is a traditional 1000 gallon tank going out to a leach field with about 100ft of perforated pipe (known as a 'traditional' system').

But traditional systems are now banned for this soil type (clay content > 50%, even though they still work fine if designed right). The current price for a traditional system is now about $5500. But since it is banned, I have to install a 'Evapotranspirative (ET) system' which involves digging two 20'x80' pits and filling it with a special 'sandy loam' soil (which is not native to the area and has to be trucked in) and then running the perforated pipe in that. It's two to three times the work and an extra $2k - $4k in soil costs.